NON-ILLUMINATED INTERIOR MESSAGE PANELS
Date: 02/18/99 (Accord 15 Modular Sign System )
PART 1 - GENERAL
** THIS SECTION INCLUDES SPECIFICATIONS FOR TOTAL INTEGRATED INTERIOR SIGN SYSTEM. SELECT APPROPRIATE TYPE OR TYPES BELOW. CONSULT MANUFACTURER'S CATALOG FOR STYLES; CONSULT MANUFACTURER'S REP. FOR COMPLETION OF SCHEDULE.
** CAVEAT: APCO supports the goal of making facilities accessible and has developed guidelines in an effort to promote voluntary compliance. APCO provides information and guidelines on the Americans with Disabilities Act (ADA) on a voluntary basis, having used extreme care and high standards to assure accuracy in interpretation of the law. However, all information, either written or verbal, is strictly an interpretation and is presented with no warranty either expressed or implied. APCO officers, staff, representatives, and/or consultants assume no legal responsibility for the accuracy of presentations, comments or other ADA information. Neither is liability assumed for the outcome of decisions, contracts, commitments or obligations made on the basis of this information. APCO guidelines are taken from the Department of Justice's final rules implementing Title III of the Americans with Disabilities Act, printed in the Federal Register, 28 CFR, Part 36, 26 July 1991. APCO recommends that anyone affected by ADA obtain a copy of The Americans with Disabilities Act and consult their legal counsel.
1.01 SUMMARY
A. Section includes: Interior non-illuminated directional, control, and information surface mounted signage as complete integrated modular system.
B. Related sections:
1. Section 01630: Product Options and Substitutions.
2. Section 03300: Cast-in-Place Concrete.
3. Section 04220: Concrete Unit Masonry.
4. Section 08110: Steel Doors and Frames.
5. Section 08210: Wood Doors.
6. Section 09260: Gypsum Board Systems.
7. Section 09510: Acoustical Ceilings.
8. Section 09900: Painting.
9. Section 09960: Vinyl Wall Covering.
C. Unit prices: Provide installed unit price for each type unit in designed system for extra possible required signage.
1.02 REFERENCES
A. Standards of the following as referenced:
1. American National Standards Institute (ANSI).
B. Industry standards:
1. Department of Justice, Office of the Attorney General, "Americans with Disabilities Act", Public Law 101-336, (ADA).
2. ANSI A117.1: Providing Accessibility and Useability for Physically Handicap People, 1986 edition.
3. Federal Register Part III, Department of Justice, Office of the Attorney General, 28 CFR Part 36: Nondiscrimination on the Basis of Disability by Public Accommodations and in Commercial Facilities, Final Rule, July 26, 1991.
4. Federal Register Part II, Architectural and Transportation Barriers Compliance Board, 36 CFR Part 1191: Americans with Disabilities Act (ADA) Accessibility Guidelines for Buildings and Facilities; Amendment to Final Guidelines, September 6, 1991.
1.04 DEFINITIONS
A. Terms:
1. Braille: Grade 2 Braille including 189 part-word or whole word contractions in addition to Grade 1 Braille 63 characters. Tactile is required whenever braille is required; see SYSTEM DESCRIPTION Article below.
2. Non-tactile: Letters and numbers on signs with width-to-height ratio between 3:5 and 1:1 and stroke width ratio between 1:5 and 1:10 using upper case "X" to calculate ratios. Use typestyles with medium weight; upper and lower case lettering is permitted; serif typestyles are permitted. See SYSTEM DESCRIPTION Article below.
3. Symbols: Symbol itself is not required to be tactile but equivalent verbal description is required both in tactile letters and braille.
4. Tactile: 1/32" raised capital letters without serifs at least 5/8" height and not more than 2" height based on upper case "X". Braille is required whenever tactile is required; see SYSTEM DESCRIPTION Article below.
1.05 SYSTEM DESCRIPTION
A. Signage under this section is intended to include items for identification, direction, control, and information of building where installed as complete integrated system from a single manufacturer.
B. ADA design requirements:
1. Signage requiring tactile graphics:
a. Wall mounted signs designating permanent rooms and spaces such as, room numbers and restroom, department, office, and fire exit identifications.
b. Individually applied characters are prohibited.
2. Signage not requiring tactile graphics but require compliance to other ADA requirements: All other signs providing direction to or information about function of space such as, directional signs (signs with arrow), informational signs (operating hours, policies, etc.), regulatory signs (no smoking, do not enter), and ceiling and projected wall mount signs.
3. Excluded signage:
a. Exterior signs.
b. Building directories.
c. Menus.
d. Temporary signs, include personnel signs and tenant identification; suite numbers are not considered temporary.
C. ADA performance requirements:
1. Tactile graphics signs mounting requirements:
a. Single doors: Mount 60" to sign centerline above finish floor and on wall adjacent to latch side of door.
b. Openings: Mount 60" to sign centerline above finish floor adjacent opening.
c. No wall space adjacent latch side of door, opening, or double doors: Mount 60" to sign centerline above finish floor on nearest adjacent wall.
1.06 SUBMITTALS
A. Product data:
1. Manufacturer's signed statement regarding compliance with QUALITY ASSURANCE Article.
2. Manufacturer's product literature indicating units and designs selected.
3. Evidence of manufacturer's computerized data retrieval program for tracking of Project for sign typography, message strip requirements and other pertinent data from schedule input to final computerized typography on finished product.
B. Shop drawings:
1. Indicate materials, sizes, configurations, and applicable substrate mountings.
2. Typography sample for message strips and headers copy.
3. Artwork for special ** graphics. ** headers. **
4. Signage schedule complete with location of each sign and required copy; include floor plans, if required.
C. Samples: Full size samples for holder, insert, and copy in colors specified. Provide sample in small size sign. Samples will ** not ** be returned for use in Project.
** MANUFACTURER HAS AVAILABLE SOFTWARE PROGRAM FOR PERSONAL COMUPTERS - PC, CALLED "SIGNWORD PRO" ENABLING END USER TO PRODUCE GRAPHICS ON INSERT OR SIGN FACE. INFO IN MAIN CATALOG OR CALL MANUFACTURER DIRECTLY AT LISTED TELEPHONE NUMBER FOR MORE INFO.
D. Contract close out:
1. Furnish appropriate checklist for aiding in reordering after Date of Substantial Completion. Maintain computer schedule program for ** five ** years for ordering new signage required by Owner.
2. Maintenance data and cleaning requirements for exterior surfaces.
**3. Furnish one complete SignWord Pro software package Windows 3.0 or Windows 95 or later, Windows NT 4.0 or later in Owner selected format for PC type computer.
**4. Furnish one complete packaged SignWord Color paper system with clear cover overlay.
1.07 QUALITY ASSURANCE
A. Qualifications:
1. Manufacturer:
a. Work required under this section from manufacturers regularly engaged in work of this magnitude and scope for minimum of five years.
b. Maintain computer link between schedule input and computerized typography production.
1.08 DELIVERY, STORAGE, AND HANDLING
A. Indicated in Delivery, Storage, and Handling Section.
** USE EITHER A. ABOVE or A. BELOW.
A. Acceptance at site: Coordinate delivery of work to Project site under this section for immediate installation.
1.09 SEQUENCING AND SCHEDULING
A. Schedule system installation after related finishes have been completed.
PART 2 - PRODUCTS
2.01 MANUFACTURED UNITS
A. Acceptable product:
1. APCO; Accord 15 Modular Sign System; SignBand system; 388 Grant Street SE, Atlanta, Georgia, 30312, USA. Phone; (404) 688-9000. Fax; (404) 577-3847.
**2. Other manufacturer's products are acceptable if submitted in accord with Product Options and Substitutions section and are in strict compliance with these specified requirements.
B. Provide the following assemblies; locate where indicated in SCHEDULES Article for Accord 15 Modular Sign System:
1. Surface Mounted Signs, Wall or Office Panel: Combination of modular aluminum bands (SignBands) which lock onto molded plastic End Clips up to 150mm/6" in height to form a single sign or stack to create module signs. Or, combination of aluminum bands (SignBands) which lock onto aluminum Side Tracks via molded plastic multiple clip fasteners, allowing for complete flexibility with size, configuration, and modularity for both single insert identification signs to large, complex directory formats and directional signs.
2. Ceiling Mounted Signs: Combination of two holder modules (either plastic End Clips or aluminum Side Tracks) back to back with corresponding insert bands(SignBands) to form ceiling suspended module providing graphic and visual information.
3. Projection Signs: Combination of two holder/insert modules back to back utilizing End Clips and SignBand Link devices to form projection mount signs providing graphic and visual information.
4. Desk Signs: Combination of End Clip and SignBand assemblies creating desk sign modules, either perpendicular or angled in relation to the desk surface, allowing for changeable graphic inserts or permanent graphic information.
5. Notice Sign: Special Notifier product designed for individual mounting or assembly mounting with various SignBand type messages, accepts hand written note paper inserted into a special roller track. Attaches to wall surface with 30mm End Clip or snaps into any Accord assembly.
C. Design units with selected components below.
** COMPONENTS LISTED BELOW GIVE ONLY GENERAL INFORMATION. SCHEDULES ARTICLE REQUIRES COMPLETE SIGNAGE SCHEDULE DEVELOPED BY MANUFACTURER'S REP.
2.02 Accord 15 - Interchangeable Sign Band Series
A. Modular Sign System:
1. End Clip System:
a. Individual band for name plate, room/floor identification use:
Sizes (Height): **150**120**90**60**45**30mm**aluminum extruded plaque surface screened or aluminum extruded insert slot **90**60**45**30mm** for SignWord paper insert ** or ADA insert.
Custom plaques using phenolic etched .080" thick, .060" acrylic.
b. Color: Selected by Architect from manufacturer's standard 44 painted colors, plastic five integral colors: 02-Black, 43-Putty, 44-Architectural Brown, 72-Bone White, and 78-Pearl Grey.
c. Modulating End Clips ** Radius ** Bevel ** Square *150mm**120mm**90mm**60mm allows for any combination SignBands
d. Mounting: ** Pin mounting ** Panel Clip ** Wall ** Desk** or custom as
indicated in SCHEDULES Article.
2. Side Track System:
a. Track aluminum edge shapes ** Large Radius ** Large Bevel ** Square **ThinLine**
b. Color: Selected by Architect from manufacturer's standard 44 painted colors; five powder coated colors, or satin anodized colors. High gloss polished finishes: **Gold**Silver** available upon request, consult factory regarding minimum requirements and lead time.
c. Track end caps **Radius**Bevel**Square**
Color: Selected by Architect from manufacturer's standard 44 painted colors; molded plastic five integral colors: 02-Black, 43-Putty, 44-Architectural Brown, 72-Bone White, and 78-Pearl Grey.
d. Mounting: Direct to wall surface ** Ceiling** Projection**or custom as indicated in SCHEDULES Article.
e. Configuration: Indicated in SCHEDULES Article.
B. Message Bands:
1. Sign Bands for Side Track System:
a. Size: Metal Band inserts:
Sizes selected from various heights:
Insert Slots feature accepting SignWord Paper** ADA inserts**noted with suffix "IS".
SB150: **150mm x 6" 8" 10" 12" 16" 18" 20" 24"
SB120: **120mm x 6" 8" 10" 12" 16" 18" 20" 24"
SB90: **90mm x 6" 8" 10" 12" 16" 18" 20" 24"
SB90IS: **90mm x 6" 8" 10" 12" 16" 18" 20" 24"
ADA Band Photopolymer:
SB90IS:**90mm x 6" 8" 10" 12"
SB60: **60mm x 6" 8" 10" 12" 16" 18" 20" 24"
SB60IS: **60mm x 6" 8" 10" 12" 16" 18" 20" 24"
ADA Band Photopolymer:
SB60IS:**60mm x 6" 8" 10" 12"
.SB45: **45mm x 6" 8" 10" 12" 16" 18" 20" 24"
SB45IS:**45mm x 6" 8" 10" 12" 16" 18" 20" 24"
ADA Band Photopolymer:
SB45IS:**45mm x 6" 8" 10" 12"
SB30: **30mm x 6" 8" 10" 12" 16" 18" 20" 24"
SB30IS:**30mm x 6" 8" 10" 12" 16" 18" 20" 24"
SB15: **15mm x 6" 8" 10" 12" 16" 18" 20" 24"
SB15IS:**15mm x 6" 8" 10" 12" 16" 18" 20" 24"
Special 30mm Slider Band for changeable messages (ie. "IN USE").
b. Expanded height sign plaques configuration.
SBE15 Expander with .080" Phenolic ADA material:
Sizes:45mm Ht. x 6" 8"10" 12" 16" 18" 20" 24"
60mm Ht. x 6" 8"10" 12" 16" 18" 20" 24"
90mm Ht. x 6" 8"10" 12" 16" 18" 20" 24"
SBE30 Expander sign plaques:
Sizes:150mm Ht. x 6" 8" 10" 12" 16" 18" 20" 24"
210mm x 6" 8" 10" 12" 16" 18" 20" 24"
255mm x 6" 8" 10" 12" 16" 18" 20" 24"
300mm x 6" 8" 10" 12" 16" 18" 20" 24"
405mm x 6" 8" 10" 12" 16" 18" 20" 24"
450mm x 6" 8" 10" 12" 16" 18" 20" 24"
510mm x 6" 8" 10" 12" 16" 18" 20" 24"
600mm x 6" 8" 10" 12" 16" 18" 20" 24"
Material: SBE30 1.5mm acrylic sheet APCO code SB241, Aluminum 1mm(.040"thick) precoated sheet or 0.080" thick ADA phenolic sheet.
c. Color: Selected by Architect from manufacturer's standard 44 painted colors.
d. Mounting: Attach to Track utilizing multiple clip plastic fastener in 15mm increments, allowing removal with manufacturer's special Removal Tool.
2. Decorative Bands
a. Size: 15mm x 6" 8" 10" 12" 16" 18" 20" 24"
**Radius**Bevel**Square**Optional Face-with decorative option to be specified in SCHEDULES Article**
b. Mounting: Attach to Track utilizing multiple clip plastic fastener in 15mm increments. Allowing removal with manufacturer's special Removal Tool.
3. SignBand Notifier
a. Size: 30mm x 4" 6" 8" 10" 12" 16" 18" 20" 24"
b. Color: Natural Satin Anodized and Polyurethane finsihes in 44 painted colors.
4. Poster Holders ** Emergency Plans
a. Poster Holder Dislpay sizes:
279 x 216mm (11 x 8.5)
297 x 210mm (11.7 x 8.27)
305 x 305mm (12 x 12)
356 x 216mm (14 x 10.2)
364 x 257mm (14.3 x 10.2)
420 x 297mm (16.5 x 11.7)
432 x 457mm (17 x 11)
457 x 457mm (18 x 18)
610 x 457mm (24 x 18)
762 x 610mm (30 x 24)
b. Emergency Plans
Sizes: 279 x 216mm (11 x 8.5)
305 x 305mm (12 x 12)
5. Configuration: Indicated in SCHEDULES Article. Select from a variation of standard configurations.
6. Copy: Indicated in SCHEDULES Article.
C. Graphics:
1. Type sizes: Selected from manufacturer's standard sizes indicated in SCHEDULES Article for particular units; meet ADA requirements for letter proportions and sizes.
** SELECT TYPE STYLE: STANDARD TYPESTYLES AT SAME COST ARE AS FOLLOWS:
HM, helvetica medium; HR, helvetica regular.
M, melior; MSB, melior semi-bold.
O, optima; OSB, optima semi-bold.
CC, craw clarendon; CCB, craw clarendon book.
E; eurostyle; EB, eurostyle bold; EBE, eurostyle bold extended; EE, eurostyle extended.
FM; Futura.
** ADA REQUIREMENTS SUGGESTS USE OF HM, OSB, and FUTURA AS RELEVANT TYPESTYLES.
2. Type style or styles: ** HM. ** HR. ** M. ** MSB. ** O. ** OSB. ** CC. ** CCB. ** E. ** EB. ** EBE. ** EE. ** FM. **
3. Type code or codes: ** Uppercase. ** Initial caps. ** Combination. ** Indicated in SCHEDULES Article. **
4. Imprint colors: Selected by Architect from manufacturer's standard 40 non-glare screening ink colors per unit and indicated in SCHEDULES Article; color contrast background colors in accord with ADA requirements.
2.03 FABRICATION
A. Shop assembly:
1. Fabricate units to configurations indicated on reviewed shop drawings. Internally reinforce units in accord with reviewed shop drawings.
2. Provide copy on inserts, ** message strips, ** headers or bases, ** and covers required on reviewed shop drawings and in accord with ADA requirements.
3. Fill directories with combination of reviewed copy on message strips and blank message strips.
4. Wrap each individual unit with polyethylene.
PART 3 - EXECUTION
3.01 EXAMINATION
A. Verification of conditions: ** Indicated in Coordination Section. ** OR **
1. Examine areas to receive signage; notify Architect in writing of unacceptable substrate.
2. Beginning work indicates acceptance of substrate. Subsequent modifications to substrate or signage becomes this section's complete responsibility.
3.02 INSTALLATION
A. Install signage holders in locations with mounting types indicated in accord with reviewed shop drawings. Square, plumb, and level units.
B. Install inserts not more than 48 hours prior to Date of Substantial Completion complete with correct copy in place. Conform to ADA requirements for tactile graphics signage.
3.03 CLEANING
A. Clean exposed surfaces not more than 48 hours prior to Date of Substantial Completion in accord with manufacturer's written cleaning instructions.
3.04 SCHEDULES
A. See attached sheet for Schedule.
END OF SECTION 10443